Troubleshooting Your Baghouse Fabric Filter

Typical issues with baghouses are opacity, high differential pressure, and shorter than expected bag life.

Opacity: Typical Causes

  • Bag failure (holes, tears, unsecured bags, new bag issues)
  • Bleed-through (blinded bags, insufficient control layer from over-cleaning)
  • Improper new bag startup procedure
  • Mechanical leakage (breach, hole in tube sheet, bypass damper leakage)
  • Improper installation

High DP: Typical Causes

  • Undersized baghouse (air-to-cloth ratio)
  • Excessive can velocity
  • Malfunctioning cleaning controller
  • Insufficient cleaning energy (e.g. reverse air an, air compressor off)
  • Isolation dampers or pulse valves not operating
  • Obstruction in hopper or ductwork
  • Bags blinded and need replacing
  • Process change/upset (tube leak, SDA, sorbent, temperature

Factors Related to Bag Life

  • Particulate grain loading
  • Excessive cleaning frequency and energy
  • Incorrect bag media choice
  • Improper new bag startup
  • Incorrect pre-coat material
  • Incorrect air-to-cloth ratio
  • High can velocity
  • Frequency of startup and shut-down
  • Changes in process or system

 

KB_FF_Troubleshooting-revised

Click to expand.

KB_FF_Troubleshooting-revised2

Click to expand.

 

 

Helpful Resources

KnowledgeBase: Misconceptions

KnowledgeBase: Operations & Maintenance

KnowledgeBase: Best Practices for Baghouse Inspections & Maintenance

Go Back

Low Emitter Status Achieved with Low-Cost Effort

LEE Status for Midwest Power Plant

A Midwest power plant called on Neundorfer to use its analytical skills, field experience and modeling capabilities to provide a low-cost/high-value solution that will allow them to achieve LEE (Low Emissions Emitter) status while forgoing the need f ...

Read the White Paper

"The Unit is consistently performing at 80% or more below the MATS limit."

LEE Status

Midwestern Utility

Back to Top