Troubleshooting ESP Discharge Electrode Suspension

Troubleshooting ESP Discharge Electrode Suspension

This article discusses suspension considerations encountered by users of weighted wire discharge electrodes.

There are two discharge electrode frames to consider in weighted wire applications:

  1. Upper wire frame from which wires are hung.
  2. Lower wire frame which maintains horizontal stability of wires by fixing the position of the wire and its attached weight

Isolating the discharge electrode system from grounded sections of the precipitator is essential for proper performance. Electrical clearances should be maintained at a distance near the plate-to-plate distance. With 9″ plate spacing, a distance of 8″ is usually acceptable, meaning that the discharge system structure should be no closer than 8″ from the nearest ground source.

The most critical consideration in the design of discharge electrode systems is the alignment of components to set and maintain electrical clearances that maintain high operating voltages.

 

Helpful Resources

KnowledgeBase: Introduction to ESP

KnowledgeBase: ESP Troubleshooting

KnowledgeBase: Major Components Overview

Our Capabilities: Precipitator Internals

Go Back

Holistic Troubleshooting Helps Resolve Baghouse Cleaning Issues

Sonic Horn Success Story

The most obvious fix turned out not to be the best one when Neundorfer helped a utility resolve baghouse cleaning issues that were limiting its ability to run at full load. Use of a multi-phase planning process and holistic troubleshooting approach y ...

Read the White Paper

"Neundorfer's holistic troubleshooting approach helped our customer complete a high-profile project and return to full load, despite budget constraints. "

Southern Coal-Fired Utility

Back to Top